skip to Main Content

tropical_logo

KEEP YOUR POOL AT PERFECT TEMPERATURE ALL SEASON LONG

  • ICEBREAKER® heat and cool – extends swimming season longer than any other heat pump on the market
  • Continues to heat at freezing temperatures to minimize heat loss
  • Cools your pool to a refreshing temperature
  • Patented high performance ThermoLink® titanium heat exchanger maximizes flow efficiency
  • Weather protected microprocessor control with full text LCD display is easy to use and compatible with most external controllers
  • Impact resistant, rust and fade proof cabinet with built-in drain pan provides condensate management
  • Quieter than conventional heat pumps
PoolSync Ready

Now you can control your heat pump right through your smartphone. Adjust your temperature setting in the PoolSync app.
*Additional purchase of PoolSync WiFi Controller required

Contact AquaCal for your Sizing Needs
ahri_cert_product   CE logo   ETL logo

AHRI’s globally recognized and industry respected heat pump pool heaters certification program provides outstanding value to equipment and component manufacturers, customers, and government regulators. AHRI Certified® products are subject to rigorous and continuous testing by a third-party laboratory under contract to AHRI. Only products certified by AHRI are listed in AHRI’s Directory of Certified Product Performance, a real-time database at web page. More information can be found online on the heat pump pool heaters Certification Program (web page), and the heat pump pool heaters contractors (web page).

California residents – Click here for Proposition 65 warning

Category:

Brochures & Manuals

Specs 60Hz

60Hz T135R
BTUs
(water temp/ambient air/relative humidity)
80/80/80 123,000
80/80/63 118,000
80/50/63 78,000
Coefficient of Performance
(water temp/ambient air/relative humidity)
80/80/80 5.5
80/80/63 5.2
80/50/63 4.0
Refrigerant R410A
Heat Exchanger ThermoLink®
Electrical
kW Input 6.7
Voltage/Hz/Phase 208-230/60/1
Minimum Circuit Ampacity 43.3
Maximum Fuse Size 60
Water Flow
Minimum/Maximum (gpm) 30/70
* A Heater Bypass Kit is required when flow rates exceed the maximum: part number STK0135.
Physical
Weight (lbs) 264
Length x Width x Height (in) 34″ x 34″x 39″
Shipping
Weight (lbs) 304
Length x Width x Height (in) 37″ x 36″x 45″
Rated in accordance with AHRI standard 1160 water temp/ambient air/relative humidity