The NEWLY redesigned HeatWave SuperQuiet® SQ120R comes equipped with all standard features. The Patented ThermoLink® Titanium Heat Exchanger at its core makes this unit a power-house that’s built to last. The SQ120R features IceBreaker® technology which allows you to heat and cool your pool. Plus, IceBreaker® units extend the swimming season longer than any other heat pump by continuing to operate in low temperatures.
- Corrosion proof cabinet with AquaTop
- Scroll Compressor – for quiet operation
- Microprocessor Controls
- Off-Set Plumbing
AHRI’s globally recognized and industry respected heat pump pool heaters certification program provides outstanding value to equipment and component manufacturers, customers, and government regulators. AHRI Certified® products are subject to rigorous and continuous testing by a third-party laboratory under contract to AHRI. Only products certified by AHRI are listed in AHRI’s Directory of Certified Product Performance, a real-time database at web page. More information can be found online on the heat pump pool heaters Certification Program (web page), and the heat pump pool heaters contractors (web page).
60 Hz | SQ120R |
---|---|
BTUs (water temp/ambient air/relative humidity) | |
80/80/80 | 110,000 |
80/80/63 | 103,000 |
80/50/63 | 72,000 |
Coefficient of Performance (water temp/ambient air/relative humidity) | |
80/80/80 | 5.5 |
80/80/63 | 5.3 |
80/50/63 | 4.0 |
Refrigerant | R410A |
Electrical | |
Heat or Heat & Cool | H & C |
kW Input | 5.9 |
Voltage/Hz/Phase A - 208-230/60/1 B - 200-230/60/3 E - 380-415/60/3 G - 460/60/3 | A & B |
Minimum/Maximum Fuse Size | A - 60 B - 50 |
Minimum Circuit Ampacity | A - 38.5 B - 31.0 |
Water Flow *A Heater Bypass Kit is required when flow rates exceed the maximum | |
Minimum/Maximum (gpm) | 30/70 |
Physical | |
Weight (lbs) | 268 |
Size (lengthxwidthxheight) | 34" x 34" x 44" |
Shipping | |
Weight (lbs) | 329 |
Size (lengthxwidthxheight) | 38" x 36" x 49" |
Rated in accordance with ARI standard 1160 water temp/ambient air/relative humidity
The only heat pump that allows you to maximize the potential savings of a variable speed pump is an AquaCal®, which utilizes our patented ThermoLink® Heat Exchanger technology with its unique flow characteristics.
• Patented hydraulic design adds only 1 PSI at 30 gpm, increasing compatibility with two-speed & variable speed pumps.
• Saves money when using a variable speed pump by reducing the RPM needed to achieve the same flow rate.
• Save money in a single speed pump application by reducing the run time needed to achieve the same turnover rate of the pool.
Corrosion Proof Cabinet
• Louvered side panels protect evaporator coil while ensuring efficient air flow
• Rust and fade proof
• Impact resistant
• Built-in drain pan provides condensate management
AquaTop
• Air Flow Vectoring Top protects internal components from weather and debris while ensuring optimal air flow
Microprocessor Controlled with Digital Display
• Flip-out control panel is out of sight, protected against sun and weather
• Lockable panel provides security from others changing the temperature
• Accurate and easy-to-read bright blue display
• On-board self diagnostics
• Microprocessor controlled defrost cycle
ThermoLink® Titanium Heat Exchanger
• Patented counter-flow water management system
• Patented hydraulic design adds only 1 PSI at 30 gpm, increasing compatibility with two-speed & variable speed pumps
• Impervious to chemical corrosion
• Durability without sacrificing performance
• Lifetime warranty
Additional Feature
IceBreaker® Technology:Heat & Cool Models
• Extends swimming season longer than any other heat pump on the market
• Continue to heat at freezing temperatures to minimize heat loss
• Cool your pool to a refreshing temperature
• Set to heat, cool or autotemp
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
60 Hz | SQ125 | SQ145 | SQ225 | SQ120R | SQ166R |
---|---|---|---|---|---|
BTUs (water temp/ambient air/relative humidity) | |||||
80/80/80 | 101,000 | 119,000 | 143,000 | 110,000 | 126,000 |
80/80/63 | 95,000 | 112,000 | 134,000 | 103,000 | 120,000 |
80/50/63 | 62,000 | 75,000 | 90,000 | 72,000 | 82,000 |
Coefficient of Performance (water temp/ambient air/relative humidity) | |||||
80/80/80 | 6.5 | 6.8 | 6.5 | 5.5 | 5.6 |
80/80/63 | 6.1 | 6.4 | 6.1 | 5.3 | 5.3 |
80/50/63 | 4.0 | 4.2 | 4.0 | 4.0 | 4.0 |
Refrigerant | R410A | R410A | R410A | R410A | R410A |
Electrical | |||||
Heat or Heat & Cool | H | H | H | H & C | H & C |
kW Input | 4.6 | 5.1 | 6.4 | 5.9 | 6.6 |
Voltage/Hz/Phase A - 208-230/60/1 B - 200-230/60/3 E - 380-415/60/3 G - 460/60/3 | A | A, B & G | A, B, E & G | A & B | A, B, E & G |
Maximum Fuse Size | A - 60 | A - 60 B - 50 G - 20 | A - 60 B - 50 E - 30 G - 25 | A - 60 B - 50 | A - 60 B - 50 E - 30 G - 25 |
Minimum Circuit Ampacity | A - 40.5 | A - 42.1 B - 31.0 G - 14.2 | A - 42.1 B - 33.3 E - 18.4 G - 16.2 | A - 38.5 B - 31.0 | A - 42.1 B - 33.3 E - 18.4 G - 16.2 |
Water Flow *A Heater Bypass Kit is required when flow rates exceed the maximum | |||||
Minimum/Maximum (gpm) | 30/70 | 30/70 | 30/70 | 30/70 | 30/70 |
Physical | |||||
Weight (lbs) | 268 | 328 | 328 | 268 | 328 |
Size (lengthxwidthxheight) | 34" x 34" x 44" | 34" x 34" x 44" | 34" x 34" x 44" | 34" x 34" x 44" | 34" x 34" x 44" |
Shipping | |||||
Weight (lbs) | 329 | 390 | 390 | 329 | 390 |
Size Length x Width x Height (in) | 38" x 36" x 49" | 38" x 36" x 49" | 38" x 36" x 49" | 38" x 36" x 49" | 38" x 36" x 49" |
Rated in accordance with ARI standard 1160 water temp/ambient air/relative humidity
50 Hz | SQ145 | SQ225 | SQ120R | SQ166R |
---|---|---|---|---|
Efficiency | ||||
KW Output | 29.3 | 35.2 | 25.8 | 31.7 |
BTU Output | 100,000 | 120,000 | 88,000 | 108,000 |
Coefficient of Performance (C.O.P) | 6.8 | 6.5 | 5.5 | 5.6 |
KW Input | 4.3 | 5.4 | 4.7 | 5.7 |
Electrical | ||||
Heat or Heat & Cool | H | H | H & C | H & C |
Voltage/Hz/Phase H - 200-240/50/1 D - 380-420/50/3 | H & D | D | H & D | D |
Minimum Circuit Ampacity | H - 38.9 D - 14.2 | D - 16.2 | H - 38.9 D - 14.2 | D - 16.2 |
Maximum Fuse Size | H - 60 D - 20 | D - 25 | H - 38.9 D - 14.2 | D - 25 |
Refrigerant | R410A | R410A | R410A | R410A |
Water Flow A Heater Bypass Kit is required when flow rates exceed the maximum | ||||
Minimum/Maximum (m3/h) | 6.8/15.9 | 6.8/15.9 | 6.8/15.9 | 6.8/15.9 |
Minimum/Maximum (gpm) | 30/70 | 30/70 | 30/70 | 30/70 |
Physical | ||||
Weight (kg) | 149 | 149 | 115 | 149 |
Weight (lb) | 328 | 328 | 253 | 328 |
Length x Width x Height (cm) | 87 x 87 x 112 | 87 x 87 x 112 | 87 x 87 x 112 | 87 x 87 x 112 |
Length x Width x Height (in) | 34" x 34" x 44" | 34" x 34" x 44" | 34" x 34" x 44" | 34" x 34" x 44" |
Shipping | ||||
Weight (kg) | 177 | 177 | 143 | 177 |
Weight (lb) | 390 | 390 | 315 | 390 |
Length x Width x Height (cm) | 97 x 92 x 125 | 97 x 92 x 125 | 97 x 92 x 125 | 97 x 92 x 125 |
Length x Width x Height (in) | 38" x 36" x 49" | 38" x 36" x 49" | 38" x 36" x 49" | 38" x 36" x 49" |