Connecting a Source Water Relay Switch
A direct connection to a source water relay switch has been provided on the terminal microprocessor.
A source water switch will automatically activate or deactivate a geothermal source pump.
DANGER
Failure to heed the following will result in injury or death.
- Deactivate power while routing wiring to control board.
- Follow all National Electric Codes (NEC) and/or State and Local guidelines.
WARNING
Failure to heed the following may result in injury or death.
- This section is only for qualified installers who are familiar with the swimming pool and spa safety standards.
- The installer must be familiar with service industry techniques.
NOTICE
Failure to heed the following may result in damage to equipment.
- The wire size connecting the relay switch must be a minimum 22-gauge, 2-conductor, low-voltage wire.
- Use Fan (dry contact) connection on the microprocessor.
- Deactivate power to heat pump.
- Remove heat pump electrical access panel.
- Route wires from the relay switch to the low voltage side of the electrical enclosure. Follow all National Electric Codes (NEC) unless State or Local guidelines supersede.
- Connect the wires to the "Fan" jumper as indicated. Polarity is not important. Please note - While this connection point is labeled "Fan", it can be used as an optional connection point for controlling a geothermal relay switch.
- Reattach heat pump access panel.
- Apply power to heat pump.