Operating Chiller (With an External Controller)
Controller with an internal thermostat control
Activating Chiller
- Set the desired temperature at the external controller.
- Use the external controller to select either the "Pool" or "Spa" to heat.
Deactivating Chiller
- Set the external controller to "OFF".
Please note - If equipped, the chiller's cooling function will be disabled when using this type of controller.
If the cooling function is needed, the chiller must be temporarily re-programed for local control.
Controller with 2 positions - ("Pool" and "Spa" - no internal thermostat control)
Activating Chiller
- Set the desired temperatures on the chiller thermostats. See "Setting Thermostats"
- Use the external controller to select either the "Pool" or "Spa" to heat.
- Rapid movement between thermostats without a "rest" between each change can cause a missed signal by the chiller.
Deactivating Chiller
- Go to the heat pump and set the mode to "OFF". See "Setting Operating Mode"
Please note - If equipped, the chiller's cooling function will be disabled when using this type of controller.
If the cooling function is needed, the chiller must be temporarily re-programed for local control.
Controller with 3 positions - ("High", "Low", and "Off" - no internal thermostat control):
Activating Chiller
- Set the desired temperatures on the chiller thermostats. See "Setting Thermostats"
- Use the external controller to select either "High" or "Low" to heat.
- When changing between thermostats, select "Off" first. Then select desired thermostat.
- Rapid movement between thermostats without a "rest" between each change can cause a missed signal by the chiller.
Deactivating Chiller
- Set the external controller to "OFF".