Analog Controls - Overview of Controls*Please refer to analog control panel diagram.
POOL/OFF/SPA Toggle Switch:
With the toggle switch in the OFF (O) position, the heat pump will be prevented from operating (however, there may be power to the unit; see "Power Light On", below). With the toggle switch positioned toward the SPA or POOL thermostat knob, and with the following conditions met: 1) water pump in operation, 2) water flowing through NOTE: heat pump Can Start with Thermostats Set to Minimum: With proper water flow and electrical power supplied to the heat pump, and either the POOL or SPA thermostat selected and set to minimum, the heat pump will run any time the water temperature falls below 60º F. To prevent the heat pump from operating at water temperatures below 60º F, position the POOL/OFF/SPA toggle switch to the middle, OFF position. Power Light On: Power Light Off: Flow Light On: |