Analog Controls - Overview of Controls
*Please refer to analog control panel diagram.
With the toggle switch in the OFF (O) position, the heat pump will be
prevented from operating (however, there may
be power to the unit; see "Power Light On", below). With the
toggle switch positioned toward the SPA or POOL
thermostat knob, and with the following conditions met: 1) water pump in
operation, 2) water flowing through
the heat pump, and, 3) electrical power to the heat pump, the heat pump will
run anytime the water temperature drops below
the thermostat setting.
NOTE: heat pump Can Start with Thermostats Set to Minimum: With proper water flow and electrical power supplied to the heat pump, and either the POOL or SPA thermostat selected and set to minimum, the heat pump will run any time the water temperature falls below 60º F. To prevent the heat pump from operating at water temperatures below 60º F, position the POOL/OFF/SPA toggle switch to the middle, OFF position.
Power Light On:
Indicates electrical power is supplied to the heat pump. The heat pump
will start if the selected
(POOL or SPA) thermostat calls for heat, and there is proper water flow
through the heat pump.
Power Light Off:
Indicates proper electrical power is not getting to the heat pump. If attempting
to operate the heat pump,
ensure any disconnect switches, or circuit breakers, are switched to the
ON position.
Flow Light On:
Indicates sufficient water flow to permit the heat pump to operate. The heat
pump will start
upon a call for heat from the selected POOL or SPA thermostat.